R599728 - BlackWing - Serial Automation Protocol Document 1 BlackWing - Serial Automation Protocol Document R599728 This document describes the Bla
PARAMETERS 10 R599728 - BlackWing - Serial Automation Protocol Document7.3.7 Gamma Table Parameter7.3.8 Mask Parameter7.3.9 Test Pattern Parameter7
PARAMETERSR599728 - BlackWing - Serial Automation Protocol Document 11 7.3.11 Projector Operation Mode Parameter7.3.12 Horizontal Pixel Adjust Parame
TALLY(RESPONSE) DATA 12 R599728 - BlackWing - Serial Automation Protocol Document 8.0 TALLY(RESPONSE) DATA The Projector will only accept and proce
INTERNAL ERRORSR599728 - BlackWing - Serial Automation Protocol Document 13 9.0 INTERNAL ERRORS Error data is returned to the external control unit w
PROJECTOR OPERATION MODES 14 R599728 - BlackWing - Serial Automation Protocol Document 10.0 PROJECTOR OPERATION MODES This section describes the Bl
SOURCER599728 - BlackWing - Serial Automation Protocol Document 15 11.0 SOURCE The input signals to projectors can be only Video Sources of three kin
COMMANDS16 R599728 - BlackWing - Serial Automation Protocol Document12.0 COMMANDSThis section describes the commands that can be used with the Projec
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 17Operation modeCommunication Examples• When specifying the back color to “black”CTL
COMMANDS18 R599728 - BlackWing - Serial Automation Protocol DocumentOperation modeCommunication Examples• When specifying "-2" (decimal) as
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 19Operation modeCommunication Examples• When specifying "-2" (decimal) as
2 R599728 - BlackWing - Serial Automation Protocol Document 12.6 Color Temperature (Blue) : ‘U0E’(55H 30H 45H) ... 1
COMMANDS20 R599728 - BlackWing - Serial Automation Protocol Document12.8 MENU Auto OFF : ‘U10’(55H 31H 30H)Definition : Controls the display menu aut
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 21Available parameters :Sleep time can be set to any of the following: 15 min., 30 m
COMMANDS22 R599728 - BlackWing - Serial Automation Protocol DocumentCommunication ExamplesCTLR ‘!’ ‘1’ SP ‘U13’ SP ‘1’ CRDLA ‘@’ ‘1’ SP ‘0’ CRCTLR ‘!
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 23Operation modeCommunication ExamplesCTLR ‘!’ ‘1’ SP ‘U15’ SP ‘1’ CRDLA ‘@’ ‘1’ SP
COMMANDS24 R599728 - BlackWing - Serial Automation Protocol DocumentOperation modeCommunication Examples• When reversing the image horizontally (Righ
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 25Operation mode* After this command has been received and processed correctly, the
COMMANDS26 R599728 - BlackWing - Serial Automation Protocol Document• Reset parameter• Tally (Response) data format when requesting current timeParam
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 27Communication Examples• When changing the ID to ‘7’ from the current setting of ‘1
COMMANDS28 R599728 - BlackWing - Serial Automation Protocol DocumentOperation modeCommunication Examples• When specifying "2.5%" as the mas
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 29Communication Examples• When specifying 1 as the picture shiftCTLR ‘!’ ‘1’ SP ‘UA2
OUTLINER599728 - BlackWing - Serial Automation Protocol Document 3 1.0 OUTLINE This document describes the protocol used for the RS-232 data communic
COMMANDS30 R599728 - BlackWing - Serial Automation Protocol Document• When setting the Power Save mode to ONCTLR ‘!’ ‘1’ SP ‘UAA’ SP ‘1’ CRDLA ‘@’ ‘1
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 31• When requesting current Horizontal Pixel Adjust (green) level data (if Horizonta
COMMANDS32 R599728 - BlackWing - Serial Automation Protocol Document• When requesting current Vertical Pixel Adjust (red) level data (if Vertical Pix
COMMANDSR599728 - BlackWing - Serial Automation Protocol Document 33CTLR ‘?’ ‘1’ SP ‘UB5’ CRDLA ‘@’ ‘1’ SP ‘0’ SP ‘6’ CR12.31 Operation Mode Query : ‘
COMMANDS34 R599728 - BlackWing - Serial Automation Protocol DocumentDLA '@' '1' SP '0' SP '10' CR
APPENDIXR599728 - BlackWing - Serial Automation Protocol Document 3513.0 APPENDIX13.1 External Control Command ListCommand Character HEXHide ‘U00’ 55H
APPENDIX36 R599728 - BlackWing - Serial Automation Protocol DocumentVertical Pixel Adjust (Green) ‘UB4’ 55H 42H 34HVertical Pixel Adjust (Blue) ‘UB5’
APPENDIXR599728 - BlackWing - Serial Automation Protocol Document 3713.2 RS-232C Port Pin Configuration13.3 ASCII to Hex Conversion Table13.4 Flow char
APPENDIX38 R599728 - BlackWing - Serial Automation Protocol DocumentExample:13.5 Flow chart of “Power OFF Control”We mention an example of flow char
APPENDIXR599728 - BlackWing - Serial Automation Protocol Document 39Example:.
DATA FORMAT 4 R599728 - BlackWing - Serial Automation Protocol Document3.2.2 Tally Data when Error Occurs Header : Indicates the beginning of the t
HEADERR599728 - BlackWing - Serial Automation Protocol Document 5 4.0 HEADER Indicates the beginning and type of communication data. 4.1 External Con
IDENTIFICATION (ID) 6 R599728 - BlackWing - Serial Automation Protocol Document 5.0 IDENTIFICATION (ID) Numeric characters are used to identify an
CARRIAGE RETURN (CR)R599728 - BlackWing - Serial Automation Protocol Document 7 6.0 CARRIAGE RETURN (CR) The carriage return (CR) is one of the contr
PARAMETERS 8 R599728 - BlackWing - Serial Automation Protocol Document7.3.1 Back Color Parameter7.3.2 Color Temperature Parameter7.3.3 Menu Display
PARAMETERSR599728 - BlackWing - Serial Automation Protocol Document 9 ‘6’ 36H ID 6‘7’ 37H ID 7‘8’ 38H ID 8‘9’ 39H ID 9‘A’ 41H ID 10‘B’ 42H ID 11‘C’ 4
Comments to this Manuals